X-ray imaging with the PILATUS 100k detector

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

X-ray imaging with the PILATUS 100k detector. / Bech, Martin; Bunk, O.; David, C.; Kraft, P.; Brönnimann, C.; Eikenberry, E.F.; Pfeiffer, F.

I: Applied Radiation and Isotopes, Bind 66, Nr. 4, 2008, s. 474-478.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Bech, M, Bunk, O, David, C, Kraft, P, Brönnimann, C, Eikenberry, EF & Pfeiffer, F 2008, 'X-ray imaging with the PILATUS 100k detector', Applied Radiation and Isotopes, bind 66, nr. 4, s. 474-478. https://doi.org/10.1016/j.apradiso.2007.10.003

APA

Bech, M., Bunk, O., David, C., Kraft, P., Brönnimann, C., Eikenberry, E. F., & Pfeiffer, F. (2008). X-ray imaging with the PILATUS 100k detector. Applied Radiation and Isotopes, 66(4), 474-478. https://doi.org/10.1016/j.apradiso.2007.10.003

Vancouver

Bech M, Bunk O, David C, Kraft P, Brönnimann C, Eikenberry EF o.a. X-ray imaging with the PILATUS 100k detector. Applied Radiation and Isotopes. 2008;66(4):474-478. https://doi.org/10.1016/j.apradiso.2007.10.003

Author

Bech, Martin ; Bunk, O. ; David, C. ; Kraft, P. ; Brönnimann, C. ; Eikenberry, E.F. ; Pfeiffer, F. / X-ray imaging with the PILATUS 100k detector. I: Applied Radiation and Isotopes. 2008 ; Bind 66, Nr. 4. s. 474-478.

Bibtex

@article{444474d0f8e111ddb219000ea68e967b,
title = "X-ray imaging with the PILATUS 100k detector",
abstract = "We report on the application of the PILATUS 100K pixel detector for medical imaging. Experimental results are presented in the form of X-ray radiographs using standard X-ray absorption contrast and a recently developed phase contrast imaging method. The results obtained with the PILATUS detector are compared to results obtained with a conventional X-ray imaging system consisting of an X-ray scintillation screen, lens optics, and a charge coupled device. Finally, the results for both systems are discussed more quantitatively based on an image power spectrum analysis. Udgivelsesdato: April",
author = "Martin Bech and O. Bunk and C. David and P. Kraft and C. Br{\"o}nnimann and E.F. Eikenberry and F. Pfeiffer",
year = "2008",
doi = "10.1016/j.apradiso.2007.10.003",
language = "English",
volume = "66",
pages = "474--478",
journal = "Applied Radiation and Isotopes",
issn = "0969-8043",
publisher = "Pergamon Press",
number = "4",

}

RIS

TY - JOUR

T1 - X-ray imaging with the PILATUS 100k detector

AU - Bech, Martin

AU - Bunk, O.

AU - David, C.

AU - Kraft, P.

AU - Brönnimann, C.

AU - Eikenberry, E.F.

AU - Pfeiffer, F.

PY - 2008

Y1 - 2008

N2 - We report on the application of the PILATUS 100K pixel detector for medical imaging. Experimental results are presented in the form of X-ray radiographs using standard X-ray absorption contrast and a recently developed phase contrast imaging method. The results obtained with the PILATUS detector are compared to results obtained with a conventional X-ray imaging system consisting of an X-ray scintillation screen, lens optics, and a charge coupled device. Finally, the results for both systems are discussed more quantitatively based on an image power spectrum analysis. Udgivelsesdato: April

AB - We report on the application of the PILATUS 100K pixel detector for medical imaging. Experimental results are presented in the form of X-ray radiographs using standard X-ray absorption contrast and a recently developed phase contrast imaging method. The results obtained with the PILATUS detector are compared to results obtained with a conventional X-ray imaging system consisting of an X-ray scintillation screen, lens optics, and a charge coupled device. Finally, the results for both systems are discussed more quantitatively based on an image power spectrum analysis. Udgivelsesdato: April

U2 - 10.1016/j.apradiso.2007.10.003

DO - 10.1016/j.apradiso.2007.10.003

M3 - Journal article

VL - 66

SP - 474

EP - 478

JO - Applied Radiation and Isotopes

JF - Applied Radiation and Isotopes

SN - 0969-8043

IS - 4

ER -

ID: 10479381