Quantification and comparison of visibility and image artifacts of a new liquid fiducial marker in a lung phantom for image-guided radiation therapy

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

Quantification and comparison of visibility and image artifacts of a new liquid fiducial marker in a lung phantom for image-guided radiation therapy. / Rydhog, Jonas Scherman; Jolck, Rasmus Irming; Andresen, Thomas Lars; Munck af Rosenschöld, Per Martin.

In: Medical Physics, Vol. 42, No. 6, 06.2015, p. 2818-2826.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Rydhog, JS, Jolck, RI, Andresen, TL & Munck af Rosenschöld, PM 2015, 'Quantification and comparison of visibility and image artifacts of a new liquid fiducial marker in a lung phantom for image-guided radiation therapy', Medical Physics, vol. 42, no. 6, pp. 2818-2826. https://doi.org/10.1118/1.4919616

APA

Rydhog, J. S., Jolck, R. I., Andresen, T. L., & Munck af Rosenschöld, P. M. (2015). Quantification and comparison of visibility and image artifacts of a new liquid fiducial marker in a lung phantom for image-guided radiation therapy. Medical Physics, 42(6), 2818-2826. https://doi.org/10.1118/1.4919616

Vancouver

Rydhog JS, Jolck RI, Andresen TL, Munck af Rosenschöld PM. Quantification and comparison of visibility and image artifacts of a new liquid fiducial marker in a lung phantom for image-guided radiation therapy. Medical Physics. 2015 Jun;42(6):2818-2826. https://doi.org/10.1118/1.4919616

Author

Rydhog, Jonas Scherman ; Jolck, Rasmus Irming ; Andresen, Thomas Lars ; Munck af Rosenschöld, Per Martin. / Quantification and comparison of visibility and image artifacts of a new liquid fiducial marker in a lung phantom for image-guided radiation therapy. In: Medical Physics. 2015 ; Vol. 42, No. 6. pp. 2818-2826.

Bibtex

@article{1a56480c7eec45ae9b0a188b7c5948e8,
title = "Quantification and comparison of visibility and image artifacts of a new liquid fiducial marker in a lung phantom for image-guided radiation therapy",
keywords = "liquid fiducial marker, contrast to noise ratio, image-guided radiation therapy, image artifacts, contrast agent",
author = "Rydhog, {Jonas Scherman} and Jolck, {Rasmus Irming} and Andresen, {Thomas Lars} and {Munck af Rosensch{\"o}ld}, {Per Martin}",
year = "2015",
month = jun,
doi = "10.1118/1.4919616",
language = "English",
volume = "42",
pages = "2818--2826",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "John Wiley and Sons, Inc.",
number = "6",

}

RIS

TY - JOUR

T1 - Quantification and comparison of visibility and image artifacts of a new liquid fiducial marker in a lung phantom for image-guided radiation therapy

AU - Rydhog, Jonas Scherman

AU - Jolck, Rasmus Irming

AU - Andresen, Thomas Lars

AU - Munck af Rosenschöld, Per Martin

PY - 2015/6

Y1 - 2015/6

KW - liquid fiducial marker

KW - contrast to noise ratio

KW - image-guided radiation therapy

KW - image artifacts

KW - contrast agent

U2 - 10.1118/1.4919616

DO - 10.1118/1.4919616

M3 - Journal article

VL - 42

SP - 2818

EP - 2826

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -

ID: 154007021